Pool ------------------- Connector, DIPs and instructions copied from an original sheet connector Components | | solder -------------------------|--|----------------- gnd |01| gnd gnd |02| gnd +5 |03| +5 +5 |04| +5 |06| +12 |07| +5 |08| contatore out motor hopper |09| contatore in audio |10| audio sw hopper |11| gnd rosso |12| verde blu |13| sync gnd |14| statistic manegement |15| coin 1 |16| coin 2 sw ticket |17| motor ticket hold 3 |18| lamp hold 3 hold 4 |19| lamp hold 4 hold 2 |20| lamp hold 2 hold 1 |21| lamp hold 1 hold 5 |22| lamp hold 5 start |23| lamp hold start cancel |24| lamp hold cancel nc |25| +5 lamp ricarica ticket + hopper |26| +12 lamp gnd |27| gnd gnd |28| gnd DIPS 1 2 3 4 5 6 7 8 on off ticket + hopper on on hopper on off ticket off on no ticket - no hopper off off 1 coin 1 credit off off 1 coin 5 credits off on 1 coin 10 credits on off 1 coin 50 credits on on five of kind yes off five of kind no on royal flush yes off royal flush no on in test on in game off Instructions STATISTICS = show in and out credits MANEGEMENT = It's the general statistic. It shows in and out credits. To cancel statistics press CANCEL for 5 seconds To change max and min value for play connect to GND the manegement pin, at the same time press toghether HOLD 2 + HOLD 4 for some seconds. The following menu will show up: HOLD 1 = modify max value for play 1 to 10 HOLD 2 = modify min value foe play 1 to 5 Press start to exit from programming mode. To unlock PCB from a possible lock: connect GND to pins component15 and solder14 for 5 seconds NB. Use lamps by 12V 0,15W Memory version: V16